Categories: Thermostats

Honeywell Smart Thermostat Not Turning ON

The Honeywell Smart Thermostat Not Turning ON problem can happen for many reasons. A faulty Honeywell Smart Thermostat, a broken HVAC system, power losses, damaged wiring, et al. Here, we list some of these causes, and offer repair tips to solve these no-run issues. First, we look at what might have happened with the Honeywell Smart Thermostat itself. Then we explore the furnace issues that can also cause no HVAC running at all.  Here, we discuss these problems, not partial-but-insufficient-heat issues.  These address the case when you get no heating or cooling. But they do not cover the cases where you get some yet not enough temperature control.

Honeywell Smart Thermostat Not Turning ON: Possible Causes

Summary of Causes

    1. Honeywell Smart Thermostat temperature offset too large.
    2. Power failure keeping HVAC unit from coming on.
    3. Honeywell Smart Thermostat not level on wall.
    4. Temperature set too low or high.
    5. Bad electrical connections.
    6. Mechanical Honeywell Smart Thermostats can bind up.
    7. Not set to correct operational mode (heating or cooling mode).

Honeywell Smart Thermostat Temperature Offset Set Too High

Problem

The Honeywell Smart Thermostat temperature display seems to show that the current room temperature never reaches the set temperature. Yet the HVAC never turns on. So in this case, the display offsets may be too high.  That is, the Honeywell Smart Thermostat  acts as if the current indoor temperature is higher than it really is. And when the t-stat thinks that the room is warmer, it will not turn the HVAC ON.

Consider this.

    • Let’s say that you set the Honeywell Smart Thermostat to 74 degrees.
    • Further, you have set your display temperature offset to +3 degrees. This makes your thermostat display a current temperature reading that is three degrees warmer than the environment actually is. In this case, when the current house temperature is 74 degrees, the Honeywell Smart Thermostat would show 77 degrees.

Now the Honeywell Smart Thermostat calls for HVAC when the temperature it reads drops below 74 degrees.  But a +3 degree offset means that the actual temp must fall to 3 degrees below 74 to get warmer. So though you set the temp to 74, you won’t get heat until the actual room temp falls below 71.  Now in apartment buildings, a room on the upper floors might easily hold at 71 degrees. So you may rarely or never feel the unit working if you set the Honeywell Smart Thermostat to 74.

Fixes

Decrease the display offset temperature. This helps assure that the temp reading on the Honeywell Smart Thermostat shows as closer to actual room temp.  Plus, an accurate display reading helps prevent the situation where your furnace does not come on enough. We suggest that you avoid setting the temperature offset to more than one degree either way (+ or – offset).

Or, just turn up the set temperature.  In this scenario, let’s say you want your place to be 74 degrees. But with the +3 degree offset, you’ll need to turn the Honeywell Smart Thermostat higher than the temperature you desire.  So you’ll have to set it to 77 degrees to get that 74 degrees actual temperature.

Power Failure Keeps Honeywell Smart Thermostat from Turning On the HVAC

A typical Honeywell Smart Thermostat, mounted but powered down, snapped onto wall plate.

Problem

The screen on Honeywell smart Honeywell Smart Thermostats looks blank or dark. No readings or status messages appear. Further, the furnace does not run. Plus, you hear no humming at the furnace. But for non intelligent t-tats you may no power loss indication, except that their backlights don’t glow. Yet the effect is still the same. The HVAC Not Turning ON. That is, that the furnace never runs, no matter the Honeywell Smart Thermostat setting.

Fixes

Honeywell thermostats often get power right from the furnace system. So, check that all furnace systems are getting electricity. Often there’s a single circuit breaker that feeds the furnace. Then there’s another that feeds the outside compressor unit in HVAC arrangements. So verify that all these breakers are ON.

Furthermore, the heating and cooling subsystems often get electricity from separate circuit breakers. So, the Honeywell Smart Thermostat could glean power from either one, although usually not both. A power outage in either system could cause Honeywell Smart Thermostat Not Turning ON. By checking that the HVAC control circuits have power, you’ve ruled out this cause of Honeywell Smart Thermostat power loss. In this way, a faulty cooling system can make the HVAC system fail too.

Honeywell Smart Thermostat Poorly Wired or Installed

A Honeywell Smart Thermostat wall plate mounted, but with wires not yet connected.

Problem

If the HVAC problem happened when you installed a new smart thermostat, you may have wired it the wrong way. Perhaps you’ve reversed the W and Y wires. This would run the cooling stage though the Honeywell smart thermostat is actually calling for heating. Other symptoms may arise too. These depend on which wires and how many of them you have connected to the wrong terminals.

Fixes

Check for correct wiring at both ends of the smart thermostat cable. At the thermostat, connect all wires to the right screw terminals in the mounting plate. Then, do likewise at the furnace. Seek help from a professional HVAC technician if you feel insecure matching these wires up with the right terminals.

Crooked Mounting May Cause Honeywell Smart Thermostat Not Turning ON

Problem

Poor leveling on older thermostats can affect how well they respond to room temperature changes. Those early models used a bi-metal spring to sense temperature. Manufacturers would affix a mercury switch to the outside end of that spring. Then, as room temperature rose and fell, the spring changed size. This caused its outer end to move back and forth in accordance with temperature changes. This in turn tipped the mercury switch ON or OFF, to bring room temperature nearer to the set temperature.

You needed proper leveling for this tipping to occur as designed. Indeed, if tilted too far off of plum or the horizontal, the HVAC system might never turn on. In this case, the mercury inside does not make the contacts as it should when the room gets too cold.

Fixes

Now you may still have a mercury and bi-metal thermostat. If so, then you should replace it with a current all-electronic model that has no moving parts. Today’s smart thermostats have more accurate sensors and many more features. Plus, modern t-stats work well, no matter how far off of level you install them. They’ll turn on the furnace correctly in the house, no matter their position.  Mount them on their sides or upside down. Or, let them dangle by the wires (although we do not recommend this).  But the point is that they will regulate your heat well, in any position.

If you cannot upgrade from an older thermostat and wires if they get in the way. Then re position the thermostat over the new holes. Finally, drive the screws into those new holes. Use wall anchors in these holes for a stronger hold.

If your t-stat is not too far out of level, try loosening the screws that hold it to the wall. Then, slide the thermostat toward level. Then, mark the wall with an erasable pencil.  Next, while holding the thermostat in that marked position, tighten the screws again.  Finally, use an eraser to clean off any visible wall markings.

The Temperature Set Too Low

The temperature at 69 degrees.

Problem

You can set thermostats way lower than the ambient temperature in your home.  During moderate days outside for instance, you might set the room temperature to 72 degrees.  But if you live in a tall building, your apartment may never fall below 72 degrees.  Thus, your furnace may never come on.

Fixes

    • If you need more warmth, try setting the temperature higher.
    • Or just be happy your furnace is not running any more than it is, especially if paying your own bills.

Bad Electrical Connections Might Cause Honeywell Smart Thermostat Not Turning ON

Honeywell T8775C1005(2) thermostat wall plate, front view, showing screw terminal connection points.

Problem

The solid copper wires in the Honeywell Smart Thermostat cable can break if flexed or bent too much. Or, maybe the installer stapled the cable with too much pressure, and shorted out the individual conductors in that cable.

This issue normally appears during new Honeywell Smart Thermostat testing only. But sometimes, this problem may not show up for decades. Plus, settling of wall beams can flex these stapled wires. So, after many years, this flexing can wear wire coverings, causing faulty or no warming.

Solutions

Replace the cable between the Honeywell Smart Thermostat and furnace. Avoid tightly stapling the wire, and don’t fasten it more than you must for a secure installation. Lay it loosely.

Mechanical Honeywell Smart Thermostats can Bind Up

Problem

Now and then with Honeywell Smart Thermostats, static electricity near them can freeze the touch screen. Also, a power surge in the home’s electrical system can do this as well. Then too, the data shown onscreen no longer updates. Further, the HVAC system may not come on. No matter how far from set temperature the room temperature is, the furnace may not run at all.

Fixes

Snapping a Honeywell Smart Thermostat onto the wall plate.

 

When this no run problem happens, try rebooting the Honeywell Smart Thermostat. Turn off its power for ten to twenty seconds. Then switch it on again. This power cycling is a literal snap with many Honeywell Smart Thermostat models. Why? Because they can detach from furnace power without having to unscrew them. Just unsnap them from wall plates. Then, wait a few seconds. And finally snap them back into place to reboot. Or, if your t-stat does not come off of the wall easily, power cycle it at the breaker box. Doing this reboots the Honeywell Smart Thermostat.

Not Set to the Correct Operational Mode (Heating or Cooling Mode)

The -System Heat / Cool Mode Setting -screen, with the mode set to OFF.

Problem

Certainly you might see Honeywell Smart Thermostat Not Turning ON, when it’s not currently n heating mode!  On our smart Honeywell Smart Thermostat,  we can set it to either heating mode, cooling mode, or OFF.  If OFF, you won’t get warmth.  Nor will any cool air flow from your registers in Cool mode.

Solution

Set the Honeywell Smart Thermostat’s operational mode to Heat.  On our Honeywell Smart Thermostat, we do this in the System tab. Just tap the Heat option and press Done to make the new setting effective.  You should soon thereafter feel some heating.

Other Honeywell Smart Thermostat Posts

    1. Honeywell Smart Thermostat Not Turning ON Heat

References

    1. Official Honeywell Smart Thermostat Support Page
    2. Where to Buy a Honeywell Smart Thermostat
admin

Recent Posts

How to Update JBL Charge 3 Speaker Firmware

Here, we show how to update JBL Charge 3 speaker firmware for this popular Bluetooth…

2 hours ago

Waterpik NSP 853

We received the Waterpik NSP-853 Power Spray Plus massaging shower head for Christmas some years…

4 hours ago

How to Turn On Bluetooth in Google Home Speaker

All smart speakers in the Google Home family now support Bluetooth.  They can act as…

4 hours ago

How to Set Sleep Timer on Google Home Speaker

Firstly, the original Google Home speaker has a sleep timer that you can set and…

5 hours ago

JBL Flip 4 Speaker Charging Instructions

Follow these JBL Flip 4 speaker charging instructions for longest play using the hidden USB…

6 hours ago

JBL Flip 4 Speaker Specs Specifications

Here, we list JBL Flip 4 speaker specs specifications.  To summarize, these cover the speaker's…

12 hours ago